Applications

Research and Testing

Test rigs are rebuilt constantly. A pressure-cycling bench, a burst test cell or a materials rig may be reconfigured between every run, and the connection system has to survive being broken and remade dozens of times without degrading. That requirement rules out most fitting types before pressure is even considered.

Why cone and thread suits research work

A compression fitting seals with a ferrule swaged permanently onto the tube. It is a one-time component — remake the joint and you are reusing a ferrule already work-hardened into its final shape.

A cone and thread joint deforms nothing permanently. Provided the cone face, seat and thread are undamaged, it can be broken and remade repeatedly at full rating. On a rig that changes weekly, that is the difference between a connection system and a consumable.

The seal is also pressure-energised: system pressure acts on the back of the cone and drives it harder into its seat, rather than working against a preload set at assembly. That is what makes 100,000 and 150,000 psi achievable.


What we supply

ComponentApplication
Cone and thread fittingsElbow, tee and cross bodies from 10,000 to 150,000 psi
High-pressure needle valvesIsolation and fine throttling, straight, angle and 3-way
Tooling setsConing and threading tube on site to the length you need
Tube and nipplesOrdered to length, or produced in-house with the tooling set
Safety head and rupture discDefined-failure overpressure protection on test cells
Relief valvesFactory-set, field-adjustable and proportional types
Pressure regulators and back pressure regulatorsSetting and holding rig pressure
Line filtersProtecting instrumentation from particulate
Pressure gauges and thermocouplesRig instrumentation
Tube supportRestraining small-bore runs under cycling load

Building the rig

Two practical points for anyone specifying a rig for the first time.

  • The connection standard changes at 20,000 psi. Below it, a sleeve sits inside the gland and grips the tube directly, with a 24° cone. At 20,000 psi and above, a collar engages a nipple with a 60° cone. Components are not interchangeable across that split — treat them as two standards.
  • Threads above 20,000 psi are left-hand on the collar and nipple. The gland threads into the body conventionally; the collar does not. Brief whoever is assembling before the first make-up.

Discuss your rig

Send the maximum working pressure, tube sizes, media and how often the circuit is reconfigured, and we will specify the fittings, nipples and tooling to build it.